Parallel operation of generators is a technically demanding procedure, usually referring to synchronizing two or more generators and connecting them together to supply power to the same load. This is mainly used for capacity expansion and redundancy.
I. Characteristics of Parallel Operation of Generators
The core characteristic of parallel operation of generators is the coordination of multiple units through synchronous control, aimed at increasing total power capacity, improving system reliability (N+1 redundancy), and optimizing operational efficiency under partial loads. It has high technical requirements and requires specialized equipment to ensure consistent voltage, frequency, and phase, and ordinary generators must not be connected in parallel directly.
Precautions for Parallel Operation of Generators
II. Strict Prohibitions for Parallel Operation of Generators (Safety Red Line)
1. It is strictly forbidden to directly parallel generators that are not of parallel type: Only generators that are clearly marked as supporting parallel functionality and are designed with corresponding control circuits can be paralleled.
2. It is strictly forbidden to arbitrarily mix generators of different brands/models: Even if all support parallel operation, usually generators of the same brand, model, and specifications are required to ensure compatibility of electrical parameters and control logic. Mixing requires professional assessment.
3. It is strictly forbidden to close the breaker without meeting synchronization conditions: Parallel operation of generators must strictly meet the four conditions of equal voltage, equal frequency, same phase, and consistent phase sequence. Modern parallel control systems complete this automatically, but during manual operation, a synchronizing device must be used to confirm.
4. It is strictly forbidden to connect the load before connecting in parallel: Parallel communication and synchronization between generators must be completed first. Only after confirming successful and stable grid connection can the public load be connected.
III. Essential Preconditions for Parallel Operation of Generators
1. Hardware Conditions for Parallel Generator Operation:
Generator unit: Must use a generator equipped with parallel operation capability (built-in parallel control module).
Connecting equipment: Use manufacturer-specified dedicated parallel cables or parallel kits. For large units, parallel control cabinets and automatic load distributors are required.
2. Electrical Conditions for Parallel Operation of Generator (Synchronization Conditions):
- Same effective voltage.
- Same output frequency.
- Phase angle difference is zero (instantaneous voltages are exactly the same).
- Same phase sequence (three-phase generators).
- Same waveform (all sine waves with low distortion).
3. Status Conditions for Parallel Operation of Generator:
The generators to be paralleled should be in a no-load, stable running state.
IV. Precautions for Parallel Operation of Generator
1. Professional Design and Installation: Except for the simple parallel connection of portable inverter generators, the design, installation, and commissioning of any fixed or multi-generator parallel system must be carried out by professional electrical engineers.
2. Standard Procedures for Parallel Operation of Generator:
- Startup: Start each unit separately and run it unloaded until stable (normal water temperature and oil pressure).
- Synchronization and Paralleling: Use automatic or manual methods, and once all synchronization conditions are met, quickly close the parallel switch.
- Loading: After the system is stable on the grid, load evenly first, then intelligently increase or decrease units according to load demands.
- Decoupling: After unloading, first disconnect the parallel connection, then stop each unit separately.
3. Load Balance Management for Parallel Operation of Generator: The parallel system should be able to automatically distribute active and reactive loads proportionally to prevent single-generator overload or reverse power operation (where a motor is driven instead of driving). Regularly check whether the load distribution is balanced.
4. Fuel and Maintenance Consistency for Parallel Operation of Generator:
- Use the same batch and grade of fuel as much as possible.
- Maintenance cycles, oil brands, and the condition of components of each unit should be kept consistent to minimize performance differences.
5. Environment and Ventilation Considerations: Parallel Operation of Generator of multiple generators produces a lot of heat and exhaust. Ensure that the installation site is well-ventilated and meets safety distance requirements.
6. Regular Testing: Even if not frequently used, the parallel generators should undergo regular load tests (e.g., monthly) to verify proper system synchronization, load distribution, and transfer functions.
V. Q&A on Parallel Operation of Generators
1. What is the main purpose of parallel operation of generators?
Capacity expansion (to meet larger loads);
Redundancy (if one fails, the other can continue to supply power);
Improve operational efficiency under light load.
2. What conditions must be met for parallel operation of generators?
The four core conditions: equal voltage, equal frequency, same phase, and consistent phase sequence (three-phase). These are usually managed by an automatic control system.
3. How is the load distributed after generators are running in parallel?
It should be controlled by an automatic load distributor to evenly distribute active and reactive power according to each generator's rated capacity, preventing overload on a single unit.
VI. Huaquan Power is a professional generator manufacturer in China
Huaquan Company was established in 2010, and its business spans multiple fields including power generation equipment, new energy storage equipment, high and low voltage complete sets of equipment, and power engineering. The company has developed three major brands: 'HQ-POWER,' 'HUAQUAN,' and 'Huaquan.' Currently, the company has grown into a strong global brand in the power industry, with cumulative global sales exceeding 1 million units.
More information about parallel operation of generators: http://www.hqstr.com/
Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD